Ocean color products depend on calibration, validation, and algorithms. Satellite sensors are routinely compared against in situ measurements to ensure that the radiances and derived products are physically meaningful.
The General Chlorophyll-a Algorithm¶
Many empirical chlorophyll-a algorithms can be written in two steps.
First, compute a log-transformed blue-green band ratio:
Then estimate chlorophyll-a using a polynomial relationship:
or equivalently:
The blue and green wavelengths differ by satellite sensor, so the coefficients through also differ by sensor and processing version. The following table shows some values for common sensors:
| Sensor | Blue Wavelength (nm) | Green Wavelength (nm) | |||||
|---|---|---|---|---|---|---|---|
| CZCS | max(443,520) | 550 | 0.3330 | -4.3770 | 7.6267 | -7.1457 | 1.6673 |
| SeaWiFS | max(443,489,510) | 555 | 0.3272 | -2.9940 | 2.7218 | -1.2259 | -0.5683 |
| MODIS | max(443,489) | 547 | 0.2424 | -2.7423 | 1.8017 | 0.0015 | -1.2280 |
| VIIRS | max(443,486) | 550 | 0.2228 | -2.4683 | 1.5867 | -0.4275 | -0.7768 |
This table was adapted from the information on the NASA Ocean Color Chlorophyll processing page.